Available

SKU # 1000005910

Havells Adjustable Thermal and Magnetic Mccb Four Pole CH Frame 50kA

Havells Adjustable Thermal and Magnetic Mccb Four Pole CH Frame 50kA


₹ 31,764.00

Quantity

Min Qty : 1



Delivery Availability

 Estimated Dispatch In 14-21 Business days

EMI Available. 

On minimum purchase of ₹ 3000/-

PAN INDIA DELIVERY
100% Genuine Products
100% Secured Payments

Product Description

Overload Setting is Adjustable (70-100)% & Short Circuit Settings is Adjustable (4-10)times of Rated Current.

Compact Size & Double Insulation

  • Space saving in the Panel and has the conductive path insulated with double shield i.e. Cover & Facia

Suitable for Switch Disconnector Purpose

  • Can be used as an Isolator

In 4Pwsn version, Neutral makes first & breaks last

  • Provision for addressing Residual Current in the Circuit.

Provision of Push to tip button

  • It is an alternate means to Trip the Breaker and also helps in checking the health of the Breaker.

Uniform front Escutcheon plate

  • Common Door Cut-out Facility provided lending Uniformity

Positive dolly position indication

  • Depicts the ON/OFF status of the breaker

Suitable for DC application

  • Offers choice of system usage

Wide range of accessories available

  • Allows precise monitoring & control of circuit with the help of varied Internal & External Accessories

Separate Main & Arching contact

  • Arching Contacts makes first and breaks last thereby lending longer life to the main contacts.

Product Specifications

  • Standard conformity: IS/ IEC 60947-2

  • Rated operational voltage: 500V AC

  • Rated Insulation Voltage: 750V AC

  • Type of Release: Thermomagnetic

  • Utilisation Category: A

  • Rated frequency: 50/60Hz

  • Ambient temp: 400C (500C on request)

  • Operating altitude: 2000 metres

  • Humidity: 0 - 90%

  • Rated impulse voltage: 8 kV

  • Rating Range: 160A - 800A

  • Type of Release: Adjustable Type

  • No. of Poles Four

  • Breaking Capacity: Icu = 50kA, Ics = 50% of Icu

Note: # All MCCB’s are with extended terminals.

Breaking Capacity Icu at 415 (kA)

Current Rating (A)

Frame

Cat No.






50

160






CH

IHLCHF0160 #

200

IHLCHF0200 #

250

IHLCHF0250 #

315

IHLCHF0315 #

400

IHLCHF0400 #

500

IHLCHF0500 #

630

IHLCHF0630 #

800

IHLCHF0800 #



Your review has been posted...!

Write a review



Purchase this product to review...!

Give your valuable Rating, Review Title & Comments...!

Holding down the CTRL key as you click a image, allows you to select more than one. Upload valid image file(s)..!

Purchase this product to review...!
Thank you for your valuable feedback..!
Sending..!
Average user rating

Rating/ 5

Overall Rating
5
80% Complete (danger)
4
3
2
1

Close X