Product Description
-
Profinet (Process Field Network) is an industrial Ethernet standard used for real-time communication and automation in manufacturing and process industries
-
It enables fast and reliable data exchange between devices, such as sensors, controllers, and actuators, supporting both time-sensitive applications and standard network traffic
-
Profinet is designed to be scalable, flexible, and compatible with various automation systems, enhancing efficiency and interoperability in industrial environments
-
Warranty and support will be provided by vendor
-
Note:*Actual product image may vary from that shown on the picture
Product Specification
| Brand | Siemens |
| Product Type | Profinet |
| Product Code | 6ES71556AA010BN0 |
| Product Series | Simatic ET 200SP |
| Product Type Designation | IM155-6PN ST, including BusAdapter BA 2x RJ45 |
| HW Functional Status | From FS03 |
| Firmware Version | V4.2 |
| FW Update Possible | Yes |
| Product Function | |
| I&M Data | Yes; I&M0 to I&M3 |
| Module Swapping During Operation (hot Swapping) | Yes; Single hot swapping |
| Isochronous Mode | No |
| Engineering With | |
| Step 7 TIA Portal Configurable/Integrated From Version | V14 |
| Step 7 Configurable/Integrated From Version | V5.5 SP4 |
| Profinet From GSD Version/GSD Revision | GSDML V2.35 |
| Supply Voltage | |
| Rated Value (DC) | 24 V |
| Permissible Range,Lower Limit (DC) | 19.2 V |
| Permissible Range,Upper Limit (DC) | 28.8 V |
| Reverse Polarity Protection | Yes |
| Short-Circuit Protection | Yes |
| Input Current | |
| Current Consumption (Rated Value) | 450 mA |
| Maximum Current Consumption | 550 mA |
| Maximum Inrush Current | 3.7 A |
| I²t | 0.09 A²·s |
| Power loss | 1.9 W |
| Address area | |
| Maximum Address Space Per Module | 256 byte; For input and output data respectively |
| Maximum Address Space Per Station | 512 byte |
| Interfaces | |
| Number Of Profinet Interfaces | 1; 2 ports (switch) |
| Interface | |
| RJ 45 (Ethernet) | Yes with BusAdapter |
| Number Of Ports | 2 with BusAdapter |
| Integrated Switch | Yes |
| Bus Adapter (Profinet) | Yes BA 2x RJ45, BA 2x FC, BA 2x M12 |
| Protocols | |
| Profinet IO Device | Yes |
| Open IE Communication | Yes |
| Profinet IO Device | |
| IRT | Yes; 250 μs to 4 ms in 125 μs frame |
| Profienergy | Yes |
| Prioritized startup | Yes |
| Shared device | Yes |
| Number of IO Controllers With Shared Device, Maximum | 2 |
| Interface Types | |
| Transmission Procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| 100 Mbps | Yes |
| Autonegotiation | Yes |
| Interrupts/Diagnostics/Status Information | |
| Status Indicator | Yes |
| Alarms | Yes |
| Diagnostics Function | Yes |
| Diagnostics Indication LED | |
| Run LED | Yes; green LED |
| Error LED | Yes; red LED |
| Maint LED | Yes; Yellow LED |
| Monitoring Of The Supply Voltage (PWR-LED) | Yes; green PWR LED |
| Connection Display Link TX/RX | Yes; 2x green link LEDs on BusAdapter |
| Potential Separation | |
| Between Profinet and All Other Circuits | Yes; 1500 V AC (type test) |
| Permissible Potential Difference | |
| Between Different Circuits | Safety extra low voltage SELV |
| Isolation | |
| Isolation Tested With | 707 V DC (type test) |
| Standards, Approvals, Certificates | |
| Network Loading Class | 2 |
| Ambient Conditions | |
| Minimum Horizontal Installation | -30 °C; No condensation |
| Maximum Horizontal Installation | 60 °C |
| Minimum Vertical Installation | -30 °C; No condensation |
| Maximum Vertical Installation | 50 °C |
| Maximum Installation Altitude Above Sea Level | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| ET-Connection via BU/BA Send | Yes; + 16 ET 200AL modules |
| Product Dimension(H x W x D) | 117 x 50 x 74 mm |
| Approx Weight | 147 g; without Bus Adapter |